Ricoh MP C3004 Field Service Manual page 1057

Hide thumbs Also See for MP C3004:
Table of Contents

Advertisement

SC No.
Type
SC No.
Type
SC919-00
D
SC No.
Type
SC925-00
B
SC925-01
B
Error Name/Error Condition/Major Cause/Solution
The external controller error is detected due to other reason shown in
SC910-01 to -03.
Refer to the instructions for the external controller
Turn the main power OFF/ON.
Error Name/Error Condition/Major Cause/Solution
External controller down
While EAC (External Application Converter), the conversion
module, was operating normally, the receipt of a power line
interrupt signal from the FLUTE serial driver was detected, of
BREAK signal from the other station was detected.
External controller and the machine had been operating correctly (*) but
the external controller was turned off or rebooted, or the video bus was
disconnected.
* Printing or scanning using the external controller.
Turn the main power OFF/ON.
Error Name/Error Condition/Major Cause/Solution
NetFile function error
NetFile function error
The NetFile file management on the HDD cannot be used, or a NetFile
management file is corrupted and operation cannot continue.
• HDD defective
• HDD inconsistency caused by power failure during HDD access,
etc.
• Software bug
Service Call 900-998
1049