7. Detailed Descriptions
Process Control
PowerON
1
ProCon :Set
2
JobEnd ProCon :Set
3
Interrupt ProCon :Set
Non-useTime
4
Procon :Set
5
Manual ProCon :Exe
6
Toner End Recovery
Initial Developer
7
Setting Process
Control

Result Code for Executing Process Control

Check the following SPs.
• SP3-012-001-010 (Front)
• SP3-012-011-020 (Center)
• SP3-012-021-030 (Rear)
Category
1220
Operative Condition
When a certain time has passed after the
previous job end
(Except when recovering from an SC or
jam)
When the value of the job end counter
becomes more than the threshold
(At job end)
When the value of the job interrupt
counter becomes more than the threshold
When the value of the non-use time
counter becomes more than the threshold
When SP 3-011 is used
After the Toner End Status is cleared
(Recovery is NOT done in the near end
status)
When the machine detects a new PCU or
development unit
Code
Result name
Related SPs
SP3-530-001
SP3-530-002
SP3-530-003
SP3-530-004
SP3-530-005
SP3-530-006
SP3-530-007
SP3-530-008
SP3-534-001 to 004
SP3-534-011 to 014
SP3-533-001 to 004
SP3-533-011 to 014
SP3-531-001 to 004
SP3-011-001 to 005
-
-