6. Troubleshooting
No.
SC838-00
[2701]
No.
SC839-00
[9001]
No.
SC840-00
1018
Type
Error Name/Error Condition/Major Cause/Solution
C
Self-diagnostic Error: Clock Generator
[xxxx]: Detailed error code
Verify error
A verify error occurred when setting data was read from the clock
generator via the I2C bus.
• Defective clock generator
• Defective I2C bus
• Defective I2C port on the CPU
Replace the controller board.
Type
Error Name/Error Condition/Major Cause/Solution
D
Self-diagnostic Error: Serial Flash
[xxxx]: Detailed error code
Serial Flash access error
USB NAND Flash ROM cannot be read.
Defective controller board
Replace the controller board.
Type
Error Name/Error Condition/Major Cause/Solution
D
EEPROM access error
• During the I/O processing, a reading error occurred. The 3rd
reading failure causes this SC code.
• During the I/O processing, a writing error occurred.
• Defective EEPROM
-