Lenovo ThinkServer RD650 User Manual page 370

12 gb/s megaraid sas
Hide thumbs Also See for ThinkServer RD650:
Table of Contents

Advertisement

12Gb/s MegaRAID SAS Software User Guide
March 2014
Number
0x0171
Warning
0x0172
Information
0x0173
Information
0x0174
Information
0x0175
Information
0x0176
Critical
0x0177
Warning
0x0178
Warning
0x0179
Warning
0x017a
Warning
0x017b
Information
0x017c
Information
0x017d
Information
0x017e
Information
0x017f
Information
0x0180
Information
0x0181
Warning
0x0182
Warning
0x0183
Information
0x0184
Warning
0x0185
Information
0x0186
Information
0x0187
Information
0x0188
Warning
0x0189
Information
0x018a
Information
0x018b
Warning
0x018c
Warning
Severity
Event Text
Level
%s is not available
%s is available
%s is used for CacheCade with
capacity 0x%lx logical blocks
%s is using CacheCade %s
%s is no longer using CacheCade %s Logged when a LD was no longer using CacheCade.
Snapshot deleted due to resource
constraints for %s in snapshot
repository %s
Auto Snapshot failed for %s in
snapshot repository %s
Controller reset on-board expander
CacheCade (%s) capacity changed
and is now 0x%lx logical blocks
Battery cannot initiate transparent
learn cycles
Premium feature %s key was applied
for - %s
Snapshot schedule properties
changed on %s
Snapshot scheduled action is due on
%s
Performance Metrics: collection
command 0x%lx
Premium feature %s key was
transferred - %s
Premium feature serial number %s
Premium feature serial number
mismatched. Key-vault serial num -
%s
Battery cannot support data
retention for more than %d hours.
Please replace the battery
%s power policy changed to %s
(from %s)
%s cannot transition to max power
savings
Host driver is loaded and operational This event is not reported to the user.
%s mirror broken
%s mirror joined
%s link %d failure in wide port
%s link %d restored in wide port
Memory module FRU is %s
Cache-vault power pack is
sub-optimal. Please replace the pack
Foreign configuration auto-import
did not import any drives
Generic Conditions when Each Event Occurs
Logged when a LD was not available.
Logged when a LD was available.
Logged when a LD was used for CacheCade with the
indicated capacity in logical blocks.
Logged when a LD was using CacheCade.
Logged when the snapshot is deleted due to resource
constraints in snapshot repository.
Logged when the Auto Snapshot is failed for a VD in
snapshot repository.
Logged when the chip reset issued to on-board expander.
Logged when the CacheCade capacity is changed along with
the current capacity.
Logged when the Battery cannot initiate transparent learn
cycles.
Logged when the Premium feature key was applied.
Logged when the Snapshot schedule properties changed.
Logged when the Snapshot scheduled action is due.
Logged during the Performance Metrics collection.
Logged when the Premium feature key was transferred.
Logged when displaying the Premium feature serial number.
Logged when Premium feature serial number mismatched.
Logged during the Battery monitoring and it displays the
remaining data retention time of the battery.
Logged when the power policy of an LD is changed.
Logged when LD cannot transition to max power savings.
Logged when the mirror is broken for an LD.
Logged when joining the LD with its broken mirror.
This event is not reported to the user.
This event is not reported to the user.
This event is not reported to the user.
This event is not reported to the user.
Logged when the Foreign configuration auto-import did not
import any drives.
LSI Corporation
- 370 -
Appendix A: Events and Messages

Advertisement

Table of Contents
loading

Table of Contents