Controller Show Commands - Lenovo ThinkServer RD650 User Manual

12 gb/s megaraid sas
Hide thumbs Also See for ThinkServer RD650:
Table of Contents

Advertisement

12Gb/s MegaRAID SAS Software User Guide
March 2014
Property Name
dimmerswitch|ds
foreignautoimport
jbod
loadbalancemode
maintainpdfailhistory
migraterate
patrolread|pr
perfmode
pi
pi import
prcorrectunconfiguredareas
prrate
rebuildrate
reconrate
restorehotspare
smartpollinterval
spinupdrivecount
spinupdelay
stoponerror
time
usefdeonlyencrypt
DPM
supportssdpatrolread
SGPIOforce
6.6.2.2

Controller Show Commands

The Storage Command Line Tool supports the following show commands:
storcli /cx show
storcli /cx show all
storcli /cx show freespace
Set Command Range
See
Dimmer Switch
Commands.
on|off
on|off
on|off
on|off
0 to 100
See
Patrol
Read.
0: Tuned to provide best IOPS, currently
applicable to non-FastPath
1: Tuned to provide least latency, currently
applicable to non-FastPath
on|off
on|off
on|off
0 to 100
0 to 100
0 to 100
on|off
0 to 65535
0 to 255
0 to 255
on|off
Valid time in yymmdd hh:mm:ss format
or systemtime
on|off
on|off
on|off
on|off
LSI Corporation
- 164 -
Working with the Storage Command Line Tool
Description
See
Dimmer Switch
Commands.
Imports foreign configuration automatically, at
boot.
Enables/disables JBOD mode; by default, drives
become system drives.Not supported by all
controllers.
Enables/disables automatic load balancing
between SAS phys or ports in a wide port
configuration.
Maintains the physical drive fail history.
Sets data migration rate in percentage.
See
Patrol
Read.
Performance tuning setting for the controller.
Enables/disables data protection on the
controller.
Enables/disables import data protection drives
on the controller.
Correct media errors during PR by writing 0s to
unconfigured areas of the disk.
Sets patrol read rate of the virtual drives in
percentage.
Sets rebuild rate of the drive in percentage.
Sets reconstruction rate for a drive in percentage.
Becomes a hot spare on insertion of a failed
drive.
Set time for polling of SMART errors in seconds.
Sets number of drives that are spun up at a time.
Sets spin-up delay between a group of drives or a
set of drives, in seconds.
Stops the MegaRAID BIOS during POST, if any
errors are encountered.
Sets the controller time to your input value or the
system time (local time in 24-hour format).
Enables/disables FDE drive-based encryption.
Enables/disables drive performance monitoring
Enables/disables patrol read for SSD drives.
Force SGPIO status per port only for four drives;
affects HPC controllers.
Chapter 6: StorCLI

Advertisement

Table of Contents
loading

Table of Contents