Lenovo ThinkServer RD650 User Manual page 367

12 gb/s megaraid sas
Hide thumbs Also See for ThinkServer RD650:
Table of Contents

Advertisement

12Gb/s MegaRAID SAS Software User Guide
March 2014
Number
0x011f
Warning
0x0120
Information
0x0121
Warning
0x0122
Information
0x0123
Information
0x0124
Warning
0x0125
Information
0x0126
Critical
0x0127
Warning
0x0128
Fatal
0x0129
Information
0x012a
Information
0x012b
Information
0x012c
Information
0x012d
Warning
0x012e
Warning
0x012f
Information
0x0130
Information
0x0131
Information
0x0132
Information
0x0133
Warning
0x0134
Information
0x0135
Information
Severity
Event Text
Level
Foreign import shall result in a
backward incompatible upgrade of
configuration metadata
Redundant path restored for PD %s
Redundant path broken for PD %s
Redundant enclosure EMM %s
inserted for EMM %s
Redundant enclosure EMM %s
removed for EMM %s
Patrol Read can't be started, as PDs
are either not ONLINE, or are in a VD
with an active process, or are in an
excluded VD
Replace Drive aborted by user on PD
%s and src is PD %s
Replace Drive aborted on hot spare
%s from %s, as hot spare needed for
rebuild
Replace Drive aborted on PD %s
from PD %s, as rebuild required in
the array
Controller cache discarded for
missing or offline VD %s
When a VD with cached data goes
offline or missing during runtime, the
cache for the VD is discarded.
Because the VD is offline, the cache
cannot be saved.
Replace Drive cannot be started as
PD %s is too small for src PD %s
Replace Drive cannot be started on
PD %s from PD %s, as SAS/SATA is
not supported in an array
Microcode update started on PD %s Logged when PD Firmware download starts.
Microcode update completed on PD
%s
Microcode update timeout on PD %s Logged when PD Firmware download does not complete
Microcode update failed on PD %s
Controller properties changed
Patrol Read properties changed
CC Schedule properties changed
Battery properties changed
Periodic Battery Relearn is pending.
Please initiate manual learn cycle as
Automatic learn is not enabled
Drive security key created
Drive security key backed up
Generic Conditions when Each Event Occurs
Currently not used in the firmware.
Logged when new path is added for the physical drives.
Logged when one path is removed.
Logged when an enclosure is added.
Logged when an enclosure is removed
Logged when none of the disks can start PR.
Logged when Replace is aborted by the user.
Logged when Replace is aborted on a Hotspare.
Logged when Replace is stopped for a higher priority rebuild
operation on a drive.
Logged when pinned cache lines are discarded for a LD.
Logged when destination PD is too small for Replace.
Logged when there is a SAS/SATA mixing violation for the
destination PD.
Logged when PD Firmware download completes.
and times out.
Logged when PD Firmware download fails.
Logged when any of the controller properties has changed.
Currently not logged in the firmware.
Logged when consistency check scheduling property has
changed.
Logged when any of the BBU properties has changed.
Logged when BBU periodic relearn is pending.
Logged when controller lock key is created.
Logged when controller lock key is backed up.
LSI Corporation