Lenovo ThinkServer RD650 User Manual page 363

12 gb/s megaraid sas
Hide thumbs Also See for ThinkServer RD650:
Table of Contents

Advertisement

12Gb/s MegaRAID SAS Software User Guide
March 2014
Number
0x00ba
Critical
0x00bb
Critical
0x00bc
Critical
0x00bd
Information
0x00be
Information
0x00bf
Information
0x00c0
Information
0x00c1
Information
0x00c2
Information
0x00c3
Warning
0x00c4
Warning
0x00c5
Fatal
0x00c6
Information
0x00c7
Information
0x00c8
Critical
0x00c9
Warning
0x00ca
Critical
0x00cb
Critical
0x00cc
Critical
0x00cd
Information
0x00ce
Critical
Severity
Event Text
Level
Enclosure %s is unstable
Enclosure %s hardware error
Enclosure %s not responding
SAS/SATA mixing not supported in
enclosure; Drive %s disabled
Enclosure (SES) hotplug on %s was
detected, but is not supported
Clustering enabled
Clustering disabled
Drive too small to be used for
auto-rebuild on %s
BBU enabled; changing WT virtual
drives to WB
BBU disabled; changing WB virtual
drives to WT
Bad block table on drive %s is 80%
full
Bad block table on drive %s is full;
unable to log block %lx
Consistency Check Aborted due to
ownership loss on %s
Background Initialization (BGI)
Aborted Due to Ownership Loss on
%s
Battery/charger problems detected;
SOH Bad
Single-bit ECC error: ECAR=%x,
ELOG=%x, (%s); warning threshold
exceeded
Single-bit ECC error: ECAR=%x,
ELOG=%x, (%s); critical threshold
exceeded
Single-bit ECC error: ECAR=%x,
ELOG=%x, (%s); further reporting
disabled
Enclosure %s Power supply %d
switched off
Enclosure %s Power supply %d
switched on
Enclosure %s Power supply %d cable
removed
Generic Conditions when Each Event Occurs
Logged when the enclosure services process reports the
sense errors.
Logged when a critical or an unrecoverable enclosure failure
has been detected by the enclosure services process.
Logged when there is no response from the enclosure.
Logged when the SAS/SATA mixing in an enclosure is being
violated.
Not reported to the user.
Logged when the clustering is enabled in the controller
properties.
Logged when the clustering is disabled in the controller
properties.
Logged when the size of the drive is not sufficient for
auto-rebuild.
Logged when changing WT virtual drives to WB and the BBU
status is good.
Logged when changing WB virtual drives to WT and the BBU
status is bad.
Logged when the Bad block table on a drive is 80% full.
Logged when the Bad block table on a drive is full and not
able to add the bad block in the Bad block table.
Logged when the Consistency Check is aborted due to
ownership is lost.
Logged when the Background Initialization (BGI) is aborted
due to ownership loss.
Logged when the battery is not presented or removed and
SOH is bad.
Logged when the Single-bit ECC errors exceeded the
warning threshold.
Logged when the Single-bit ECC errors exceeded the critical
threshold.
Logged when the Single-bit ECC errors exceeded all the
thresholds and disable further logging.
Logged when the enclosure services process has detected
that the Enclosure Power supply is switched off and it was
switched on earlier.
Logged when the enclosure services process has detected
that the Enclosure Power supply is switched on and it was
switched off earlier.
Logged when the enclosure services process has detected
that the Enclosure Power supply cable is removed and it was
inserted earlier.
LSI Corporation
- 363 -
Appendix A: Events and Messages

Advertisement

Table of Contents
loading

Table of Contents