Lenovo ThinkServer RD650 User Manual page 357

12 gb/s megaraid sas
Hide thumbs Also See for ThinkServer RD650:
Table of Contents

Advertisement

12Gb/s MegaRAID SAS Software User Guide
March 2014
Number
0x0025
Information
0x0026
Information
0x0027
Information
0x0028
Information
0x0029
Information
0x002a
Information
0x002b
Information
0x002c
Information
0x002d
Information
0x002e
Warning
0x002f
Warning
0x0030
Information
0x0031
Fatal
0x0032
Fatal
0x0033
Critical
0x0034
Progress
0x0035
Information
0x0036
Information
0x0038
Warning
0x0039
Warning
0x003a
Information
0x003b
Information
0x003c
Fatal
0x003d
Critical
0x003e
Fatal
Severity
Event Text
Level
Patrol Read Rate changed to %d%% Logged to indicate progress of patrol read in percentage.
Patrol Read resumed
Patrol Read started
Reconstruction rate changed to
%d%%"
Drive group modification rate
changed to %d%%
Shutdown command received from
host
Test event: %s
Time established as %s; (%d seconds
since power on)
User entered firmware debugger
Background Initialization aborted on
%s
Background Initialization corrected
medium error (%s at %lx
Background Initialization completed
on %s
Background Initialization completed
with uncorrectable errors on %s
Background Initialization detected
uncorrectable double medium errors
(%s at %lx on %s)
Background Initialization failed on
%s
Background Initialization progress
on %s is %s
Background Initialization started on
%s
Policy change on %s from %s to %s
Consistency Check aborted on %s
Consistency Check corrected
medium error (%s at %lx
Consistency Check done on %s
Consistency Check done with
corrections on %s
Consistency Check detected
uncorrectable double medium errors
(%s at %lx on %s)
Consistency Check failed on %s
Consistency Check completed with
uncorrectable data on %s
Generic Conditions when Each Event Occurs
Logged when patrol read is resumed.
Logged when patrol read is started.
Logged to indicate progress of reconstruction in percentage.
Logged to indicate the change in Drive group modification
frequency.
Logged when shutdown command is received from host to
controller.
General controller event, with a generic string.
Logged when controller time was set from host, also
displaying time since power on in seconds.
Logged when user enters controller debug shell.
Logged to inform about user aborted background
initialization on displayed LD number.
logged to inform about corrected medium error on displayed
LD number, LBALBA number, PD number and PDLBA number
in that order.
Logged to inform Background Initialization completion on
displayed LD.
Logged to inform Background Initialization completion with
error on displayed LD.
Logged to inform Background Initialization completion with
double medium error on displayed PD, PDLBA and LD in that
order.
Logged to inform Background Initialization failure on
displayed LD.
Logged to inform Background Initialization progress in
percentage of displayed LD.
Logged to inform Background Initialization started for
displayed LD.
Logged to inform the changed policy for displayed LD with
old and new policies.
Logged to inform aborted Consistency check for displayed
LD.
Logged when Consistency check corrected medium error.
Logged when Consistency check has completed successfully
on the LD.
Logged when Consistency check completed and
inconsistency was found during check and was corrected.
Logged when uncorrectable double medium error are
detected while consistency check.
Logged when Consistency check failed as fatal error was
found.
Logged when Uncorrectable error occurred during
consistency check.
LSI Corporation
- 357 -
Appendix A: Events and Messages

Advertisement

Table of Contents
loading

Table of Contents