12Gb/s MegaRAID SAS Software User Guide
March 2014
Figure 219 CacheCade SSD Caching Wizard - First Screen
2.
Select a RAID level for the CacheCade virtual drive in the RAID level field.
3.
Select an unconfigured SSD drive, for the selected RAID level, from Select unconfigured SSD Drives in the left
frame.
After you select an unconfigured SSD Drive, the Add button is enabled.
4.
Click Add to add the selected drive to the CacheCade - SSD Caching Drive groups in the right frame.
After you click Add, the Create Drive Group button is enabled.
5.
Click Create Drive Group.
The newly created drive group appears in CacheCade SSD Caching Drive groups in the right frame.
6.
Click Next.
The next wizard screen appears.
LSI Corporation
- 336 -
Chapter 12: Using MegaRAID Advanced Software
Using the MegaRAID CacheCade Pro 2.0 Software