Lenovo ThinkServer RD650 User Manual page 360

12 gb/s megaraid sas
Hide thumbs Also See for ThinkServer RD650:
Table of Contents

Advertisement

12Gb/s MegaRAID SAS Software User Guide
March 2014
Number
0x0071
Warning
0x0072
Information
0x0073
Information
0x0074
Warning
0x0075
Information
0x0076
Information
0x0077
Critical
0x0078
Critical
0x0079
Critical
0x007a
Critical
0x007b
Critical
0x007c
Critical
0x007d
Critical
0x007e
Critical
0x007f
Critical
0x0080
Critical
0x0081
Critical
0x0082
Critical
0x0083
Fatal
0x0084
Information
0x0085
Information
0x0086
Critical
0x0087
Information
0x0088
Information
0x0089
Critical
0x008a
Information
Severity
Event Text
Level
Unexpected sense: %s, CDB%s,
Sense: %s
State change on %s from %s to %s
State change by user on %s from %s
to %s
Redundant path to %s broken
Redundant path to %s restored
Dedicated Hot Spare Drive %s no
longer useful due to deleted drive
group
SAS topology error: Loop detected
SAS topology error: Unaddressable
device
SAS topology error: Multiple ports to
the same SAS address
SAS topology error: Expander error
SAS topology error: SMP timeout
SAS topology error: Out of route
entries
SAS topology error: Index not found Logged when device discovery fails for a SAS device as
SAS topology error: SMP function
failed
SAS topology error: SMP CRC error
SAS topology error: Multiple
subtractive
SAS topology error: Table to table
SAS topology error: Multiple paths
Unable to access device %s
Dedicated Hot Spare created on %s
(%s)
Dedicated Hot Spare %s disabled
Dedicated Hot Spare %s no longer
useful for all drive groups
Global Hot Spare created on %s (%s) Logged when a drive is configured as a global hot spare.
Global Hot Spare %s disabled
Global Hot Spare does not cover all
drive groups
Created %s}
Generic Conditions when Each Event Occurs
Logged when an I/O fails due to unexpected reasons and
sense data needs to be logged.
Logged when the state of a drive is changed by the firmware
or by you.
Not logged by the firmware.
Not logged by the firmware.
Not logged by the firmware
Not logged by the firmware.
Logged when device discovery fails for a SAS device as a loop
was detected.
Logged when device discovery fails for a SAS device as an
unaddressable device was found.
Logged when device discovery fails for a SAS device multiple
ports with same SAS address were detected.
Not logged by the firmware.
Logged when device discovery fails for a SAS device due to
SMP timeout.
Logged when device discovery fails for a SAS device as
expander route table is out of entries.
expander route table out of entries.
Logged when device discovery fails for a SAS device due to
SMP function failure.
Logged when device discovery fails for a SAS device due to
SMP CRC error.
Logged when device discovery fails for a SAS device as a
subtractive-to-subtractive link was detected.
Logged when device discovery fails for a SAS device as
table-to-table link was detected.
Not logged by the firmware.
Logged when the inserted drive is bad and unusable.
Logged when a drive is configured as a dedicated spare.
Logged when a drive is removes as a dedicated spare.
Logged when an array with a dedicated spare is resized. The
hot spare (dedicated to this array and possibly others) will
not be applicable to other arrays.
Logged when a drive configured as global host spare fails or
is unconfigured by you.
Logged when the global hotspare is too small (or doesn't
meet the SAS/SATA restricitons) to cover certain arrays.