Table 4-5 Causes Of Errors For Job_Err - Siemens simatic et 200s Operating Instructions Manual

Positioning
Hide thumbs Also See for simatic et 200s:
Table of Contents

Advertisement

Causes of Errors for JOB_ERR
Table 4-5
Causes of Errors for JOB_ERR
Error Number
Meaning
21
JOB unknown
23
ERR_ENCODER is displayed
30
Evaluating the Reference Signal: Reference point
coordinates ≥ end of rotary axis
34
Setting an Actual Value: actual value coordinates
≥ end of rotary axis
35
Display current values: Selection unknown
36
Latch Function: Edge selection unknown
37
Display current values: JOB 15 cannot be
activated with the latch function running.
38
Monitoring of the direction of rotation
Path difference > 65 535
40
Voltage setting
Rapid feed speed > 32 511
41
Voltage setting creep feed speed > 32 511
42
Changing the acceleration T
43
Deceleration T
ET 200S Positioning
Operating Instructions, 05/2007, A5E00124871-04
> 65 535
acc
> 65 535
dec
4.6 Functions of the 1PosInc/Analog
Remedy
Permissible JOBs are:
JOB 0
JOB 1
JOB 3
JOB 4
JOB 9
JOB 10
JOB 11
JOB 15
Check the encoder wiring