1PosUniversal/Digital

7.8 Parameter List

7.8
Parameter List
Overview
Parameter List at Incremental Encoders with 5 V Differential Signals
Parameters
Enables
Group diagnostics
Encoder signal
diagnostics
Zero marker
diagnostics
Axis
Dosing operation
Reversal of the
direction of rotation
Axis type
End of rotary axis
Digital Inputs
DI0 limit switch minus
DI1 limit switch plus
DI2 reducing cam
368
Meaning
When group diagnostics is enabled, an
encoder error (ERR_ENCODER), no load
voltage (ERR_2L+) or a parameter
assignment error will result in a channel-
specific diagnostics.
Encoder signals A, /A and B, /B are
monitored for short circuit and wire break.
In addition the signal sequence is
monitored. A simultaneous edge change at
Signals A and B causes an error.
Zero marker signals N, /N are monitored for
short circuit and wire break.
Only the encoder signals A and /A are
evaluated. This means that only a path
change in the positive direction is possible.
Adjustment of the direction of rotation of the
encoder A reversal of the direction of
rotation is only possible if no dosing
operation is set.
Selection of linear axis without limits or
rotary axis with overrun/underrun with
encoder range
Only relevant for rotary axis type:
Underrun: 0 to end of rotary axis - 1
End of rotary axis - 1 to 0
Switch on the DI0 digital input is a break or
make contact
Switch on the DI1 digital input is a break or
make contact
Switch on the DI2 digital input is a break or
make contact
Value range
Disable
Enable
On
Off
On
Off
Off
On
Off
On
Linear
Rotary
1 - 16 777 215
Break contact
Make contact
Break contact
Make contact
Break contact
Make contact
Operating Instructions, 05/2007, A5E00124871-04
Default setting
Disable
On
On
Off
Off
Linear
36 000
Break contact
Break contact
Make contact
ET 200S Positioning