Siemens simatic et 200s Operating Instructions Manual page 295

Positioning
Hide thumbs Also See for simatic et 200s:
Table of Contents

Advertisement

Error Number
Meaning
33
With JOB 2: Offset not in encoder range
34
Setting an Actual Value: Actual value coordinates
≥ encoder range
35
Display current values: Selection unknown
36
Latch Function: Edge selection unknown
37
Display current values: JOB 15 cannot be
activated with the latch function running.
38
Monitoring of the direction of rotation
Path difference > 65 535
40
Voltage setting
Rapid feed speed > 32 511
41
Voltage setting creep feed speed > 32 511
42
Changing the acceleration T
43
Deceleration T
ET 200S Positioning
Operating Instructions, 05/2007, A5E00124871-04
> 65 535
acc
> 65 535
dec
6.6 Functions of the 1PosSSI/Analog
Remedy
1PosSSI/Analog
295

Advertisement

Table of Contents
loading

Table of Contents