Siemens simatic et 200s Operating Instructions Manual page 111

Positioning
Hide thumbs Also See for simatic et 200s:
Table of Contents

Advertisement

Technical Data of the 1PosInc/Digital
Output current
Switch rate
Lamp load
Output delay (resistive load, output current 0.5 A)
Short-circuit protection of the output
Threshold on
Inductive extinction
Digital input control
Cable lengths
Encoder signals
Length of cable
Status, Diagnostics
Change in actual value (up)
Change in actual value (down)
Status display positioning in operation
Status display DI0 (minus hardware limit switch)
Status display DI1 (plus hardware limit switch)
Status display DI2 (reducing cam)
Group error on 1PosInc/Digital
Diagnostic information
Response Times
Update rate for feedback messages
Response time at the switchover or switch-off point
Latch response time
ET 200S Positioning
Operating Instructions, 05/2007, A5E00124871-04
0 signal (leakage current)
1 signal
Rated value
Permitted range
Resistive load
Inductive load
Lamp load
At 0 to 1
At 1 to 0
Unshielded
Shielded
Level
Terminating resistance
Differential input voltage
Max. frequency
Galvanic isolation from ET200S bus
Shielded
3.10 Technical Specifications
≤ 0.3 mA
0.5 A
7 mA to 0.6 A
100 Hz
2 Hz
≤ 10 Hz
≤5 W
typ. 150 µs
typ. 150 µs
Yes
0.7 A to 1.8 A
Yes; L+ -(55 to 60 V)
Yes
600 m
1000 m
After RS 422
330 Ω
min. 1 V
500 kHz
Yes
Max. 50 m
UP LED (green)
DN LED (green)
LED POS (green)
LED 9 (green)
LED 13 (green)
LED 14 (green)
SF LED (red)
Yes
2 ms
Output delay + 30 µs
Typ. 400 µs
1PosInc/Digital
111