Moving The Encoder Range (Job 2) - Siemens simatic et 200s Operating Instructions Manual

Positioning
Hide thumbs Also See for simatic et 200s:
Table of Contents

Advertisement

1PosUniversal/Digital
7.6 Functions of the 1PosU
7.6.11

Moving the Encoder Range (JOB 2)

Definition
The move encoder range function can only be executed at SSI encoders.
When the encoder range is moved, the encoder value is adjusted so that the actual value
displayed corresponds to the real actual value. Before this can be done, any active run must
be terminated.
Supply the control interface with the offset, and activate JOB 2.
You calculate the offset as follows:
● Offset = displayed actual value – real actual value
If the offset is negative, proceed as follows:
● Offset = displayed actual value - real actual value +
The 1PosU accepts the preset offset and displays the real actual value coordinates at the
feedback interface.
Effect on the MODEs
MODEs are not affected by JOB 2.
Control Signals: Move Encoder Range
Address
Byte 4
Bytes 5 to 7
Feedback Signals: Move Encoder Range
Address
Bytes 1 to 3
Byte 4
348
(number of rotations * number of increments)
Assignment
Bits 4.7 to 4.4 :
Bit
Bit 0: JOB_REQ
Offset
(0 to encoder range)
Assignment
Actual value
(0 to encoder range - 1)
Bit 1: JOB_ERR
Bit 0: JOB_ACK
7
6
5
4
0
0
1
0
JOB 2 = Move encoder range
Operating Instructions, 05/2007, A5E00124871-04
ET 200S Positioning

Advertisement

Table of Contents
loading