1PosInc/Digital
3.6 Functions of the 1PosInc/Digital
After the reference signal has been traversed, the axis is synchronized. The 1PosInc/Digital
sets the feedback signal SYNC = 1 and assigns the reference point coordinates to the actual
value.
Figure 3-9
72
Sequence of Execution of the Search for Reference
Operating Instructions, 05/2007, A5E00124871-04