1PosSSI/Digital
5.6 Functions of the 1PosSSI/Digital
5.6.9

Setting the Actual Value (JOB 1)

Definition
Setting an actual value assigns new coordinates to the actual value displayed. This moves
the operating range to another part of the axis.
At the switchover point the 1PosInc/Digital switches from rapid feed to creep feed, and at the
switch-off it terminates the run.
The 1PosSSI/Digital sets the specified actual value coordinates on the actual value
displayed in the feedback interface and sets the feedback bit SYNC = 1.
Effect on the MODEs
MODE
Inching
Absolute Positioning
Relative Positioning
Control Signals: Setting of Actual Value
Address
Byte 4
Bytes 5 to 7
218
What Happens
-
The following responses are possible:
Distance to the destination ≤ switch-off difference
The switch-off point is reached or overshot; positioning is switched off
immediately, and the run is terminated with POS_DONE = 1. In this
case, the destination is sometimes overshot.
Distance to the destination ≤ the switchover difference
The switchover point is reached or overshot; there is an immediate
reduction from rapid feed to creep feed. In this case the distance
covered in creep feed is less than (switchover difference - switch-off
difference).
Distance to the destination > the switchover difference
The drive is moved using rapid feed, even if it was switched over to
creep feed beforehand.
The preset distance continues to be traversed.
Assignment
Bits 4.7 to 4.4 :
Bit
7
6
0
0
Bit 0: JOB_REQ
Actual value coordinates
(0 to encoder range - 1)
5
4
JOB 1 = Set the actual value
0
1
Operating Instructions, 05/2007, A5E00124871-04