1PosSSI/Analog
6.6 Functions of the 1PosSSI/Analog
Parameters
Switchover difference
Acceleration T
in ms Time required for a change in voltage
acc
Deceleration T
in ms Time required for a change in voltage
dec
Displaying the Status of the Run
You can read the status of the run from the feedback interface from byte 0, bits 5 and 6. This
status display is possible in the absolute and relative positioning MODEs.
Table 6-3
Interpretation of Bits 5 and 6
Bit 5
Bit 6
Meaning
0
0
Quiet state or run completed
0
1
Acceleration to rapid feed or run with rapid feed
1
0
Deceleration to creep feed or run with creep feed
1
1
Deceleration to 0 V
Figure 6-9
260
Meaning
Defines the distance from the
destination at which the drive is slowed
down from rapid feed to creep feed.
via a ramp from 0 V to10 V.
At 0 ms acceleration is without a ramp.
via a ramp from 10 V to 0 V.
At 0 ms deceleration is without a ramp.
Schematic Diagram of the Status of the Run
Value range
0 - 65 535
0 - 65 535
0 - 65 535
Operating Instructions, 05/2007, A5E00124871-04
Default setting
1000
10000
10000
Corresponding Number in
Figure
0
1
2
3
ET 200S Positioning