1PosSSI/Analog
6.6 Functions of the 1PosSSI/Analog
Parameters: Define the variables that depend on the drive, axis, and encoder uniquely in the
parameters.
Figure 6-4
Interfaces to the Control Program and the Axis
To execute the function, the 1PosSSI/Analog has digital inputs as an interface to the axis,
encoder signals for the connection of an encoder, and an analog and a digital output to
control the drive.
You can modify and monitor the types of motion (MODES) and functions (JOBs) with your
control program using control signals and feedback signals.
See also
Parameter List (Page 298)
254
How the 1PosSSI/Analog Works
Operating Instructions, 05/2007, A5E00124871-04
ET 200S Positioning