Sign In
Upload
Manuals
Brands
SMA Manuals
Control Unit
DATA MANAGER M
SMA DATA MANAGER M PV System Monitoring Manuals
Manuals and User Guides for SMA DATA MANAGER M PV System Monitoring. We have
4
SMA DATA MANAGER M PV System Monitoring manuals available for free PDF download: Operating Manual, Technical Information
SMA DATA MANAGER M Operating Manual (84 pages)
Brand:
SMA
| Category:
Controller
| Size: 1 MB
Table of Contents
Legal Provisions
2
Software Licenses
2
Table of Contents
4
Information on this Document
10
Validity
10
Target Group
10
Content and Structure of this Document
10
Levels of Warning Messages
10
Symbols in the Document
11
Typographies in the Document
11
Designations in the Document
11
Additional Information
12
Safety
13
Intended Use
13
Important Safety Instructions
14
Scope of Delivery
16
Product Overview
17
Device Function
17
System Manager
17
Product Description
18
Symbols on the Product
18
Reset Button
19
LED Signals
20
Interfaces and Functions
21
Wi-Fi Access Point
21
SMA Speedwire
21
Modbus
21
Sunspec Modbus
22
User Interface
22
Sunny Portal
22
Dashboard
23
Plant-Wide Parameterization
23
Energy Monitoring
23
FTP Push
23
SMA Smart Connected
23
Grid Management Services
23
Reactive Power Control
24
Zero Export
24
Active Power Limitation
24
Direct Selling
24
Device Key (DEV KEY)
24
Mounting
25
Requirements for Mounting
25
Requirements for the Mounting Location
25
Permitted and Prohibited Mounting Positions
25
Dimensions for Mounting
26
Recommended Clearances for Mounting
26
Mounting the Product on the DIN Rail
26
Mounting the Product on the Wall
27
Connection
28
Requirements for the Connection
28
Connection Cable Requirements for Power Supply Terminal X1
28
Signal Cable Requirements for Fast Stop X2
28
Signal Cable Requirements for Multifunction Relay X3
28
Signal Cable Requirements for Analog Terminals X4 to X7
28
Signal Cable Requirements for Temperature Input X8
28
RS485 X9 Cable Requirements
28
Signal Cable Requirements for Digital Terminals X10 to X13
29
Network Cable Requirements X14 to X16
29
Overview of the Connection Area
29
Preparing the Connection Cable
30
Terminal for Fast Stop X2
31
Fast Stop X2
31
PIN Assignment X2
31
Circuitry Overview X2
31
Connect Switch for Fast Stop to X2
31
Connection to the Multifunction Relay X3
32
Digital Output X3 (MFR)
32
Pin Assignment X3 (MFR)
32
Circuitry Overview X3
33
Connecting Signal Source to X3
33
Connection to the Analog Output X4/X5
33
Analog Outputs X4/X5
33
PIN Assignment X4
34
PIN Assignment X5
34
Circuitry Overview X4/X5
34
Connecting the Remote Terminal to X4/X5
34
Connection to the Analog Input X6/X7
35
Analog Inputs X6/X7
35
PIN Assignment X6
35
PIN Assignment X7
36
Circuitry Overview X6/X7
36
Connecting Signal Source to X6/X7
36
Connection to Temperature Input X8
37
Temperature Input X8
37
PIN Assignment X8
37
Circuitry Overview X8
37
Connecting Temperature Sensor to X8
38
Connection to the RS485 X9 Input
38
RS485 Input X9
38
PIN Assignment X9
39
Circuitry Overview X9
39
Connecting RS485 Devices to X9
39
Connection to Digital Input X10
40
Digital Inputs X10
40
PIN Assignment X10
41
Circuitry Overview X10
41
Connecting Signal Source to X10
42
Connection to Digital Input X11
42
Digital Inputs X11
42
PIN Assignment X11
43
Circuitry Overview X11
43
Connecting Signal Source to X11
43
Connection to the Multifunction Relay X12/X13
44
Digital Output X12/X13 (MFR)
44
Pin Assignment X12 (MFR)
44
Pin Assignment X13 (MFR)
44
Circuitry Overview X12/X13
45
Connecting Signal Source to X12/X13
45
Connection to the System Network X14/X15
45
System Network X14/X15
45
Connecting Network Cables to X14/X15
46
Connection to the Internet X16
46
Internet X16
46
Connecting Network Cable to X16
46
Connection to the Voltage Supply X1
47
Voltage Supply X1
47
PIN Assignment X1
47
Circuitry Overview X1
47
Connecting the Voltage Supply to X1
48
Commissioning
50
Requirements for Commissioning
50
Changing the Network Configuration
50
Starting the Installation Assistant
50
Establishing a Connection to the User Interface
51
Connection in the Local Network
51
Access Addresses for the Product in the Local Network
51
Ports for Data Communication in the Local Network
51
Establishing a Connection in the Local Network
52
Direct Connection Via Wi-Fi
52
Connection Options for Wi-Fi Direct Connection
52
Access Information for Direct Wi-Fi Connection
53
Establishing a Direct Wi-Fi Connection by Entering the Wi-Fi Data
53
Establishing a Direct Wi-Fi Connection by Scanning the QR Code
53
Registration in Sunny Portal
54
Profiles for Data Communication
54
Register as a New User in Sunny Portal
54
Log in to Sunny Portal as an Existing User
55
Create New PV System
55
Add Product to an Existing System
56
Operation
57
Design of the User Interface
57
Access Rights to the User Interface
58
Device Administration
58
Register Devices
58
Delete Devices
59
Backup File
59
Function and Content of the Backup File
59
Creating a Backup File
60
Upload Backup File
60
Resetting the Product to Default Setting
61
Deleting the Admin Account
61
Firmware Update
61
Carry out a Manual Firmware Update
61
Automatically Updating the Firmware
62
Automatically Updating the Firmware of Connected Devices
63
Grid Management Service
63
Active Power Limitation
63
Configuring Active and Reactive Power Setpoints
64
Configure Additional Specifications from the Grid Operator for the Country Data Set
64
Configure Additional Direct Seller's Specifications for the Country Data Set
65
Modbus
66
SMA Modbus Profile
66
Sunspec Modbus Profile
66
Creating a New Modbus Profile
66
Registering a New Modbus Device and Assigning a Modbus Profile
67
Limiting-Value Based Switching
67
Operators for Limit-Based Switching
67
Parameter for Limit-Based Switching
67
Switch Digital Outputs Based on Thresholds
68
Speedwire Encryption
68
Speedwire Encryption of the System Communication
68
Enabling Speedwire Encryption
68
Fallback Behavior
69
Function of the Fallback Behavior
69
Fallback Behavior in the Event of Communication Failure to the Digital Inputs
69
Fallback Behavior in the Event of Communication Failure to the Energy Meter at the Point of Interconnection
69
Fallback Behavior in Reactive Power Mode
69
Replace the SMA Data Manager M (EDMM-10) with the SMA Data Manager M (EDMM-20)
70
Troubleshooting
72
Obsolete or Incorrect Measured Values Are Displayed
72
Not All Devices Are Being Detected
72
The Product User Interface Cannot be Called up
72
Parameter Changes Via the Device Settings or a Parameter Adjustment Are Not Confirmed
73
The Product Cannot be Registered in Sunny Portal
73
The Firmware of a Connected SMA Product was Not Updated During a Firmware Update
73
No Data Are Displayed on the User Interface of the Product
74
Decommissioning the Product
75
Disposal
76
Technical Data
77
Communication
77
Voltage Supply
77
Climatic Conditions
77
General Data
77
Digital Inputs
78
Digital Output (Multifunction Relay)
78
Analog Inputs
78
Analog Outputs
78
Temperature Inputs
78
RS485 Inputs
79
Equipment
79
Accessories
80
Compliance Information
81
EU Declaration of Conformity
82
Contact
83
Advertisement
SMA DATA MANAGER M Operating Manual (70 pages)
Brand:
SMA
| Category:
Control Systems
| Size: 1 MB
Table of Contents
Table of Contents
5
Information on this Document
7
Validity
7
Target Group
7
Content and Structure of this Document
7
Levels of Warning Messages
7
Symbols in the Document
8
Typographical Elements in the Document
8
Designations in the Document
8
Additional Information
9
Safety
10
Intended Use
10
Important Safety Instructions
10
Supported Products
13
Scope of Delivery
16
Product Overview
17
Product Description
17
Symbols on the Product
18
Function Button
19
LED Signals
19
Sunny Portal
21
Interfaces and Functions
21
Mounting
26
Requirements for Mounting
26
Mounting the Product
27
Connection
29
Overview of the Connection Area
29
Preparing the Connection Cable
29
Connecting Signal Source to Digital Input
29
Connecting RS485 Devices
31
Connecting the Network
33
Connecting the Voltage Supply
34
Replacing SMA Com Gateway with RS485 Devices
36
Commissioning
38
Establishing a Direct Connection Via WLAN
38
Establishing a Connection Via Ethernet in the Local Network
39
Commissioning the Product
40
Registering in Sunny Portal
41
Operation
44
Design of the User Interface
44
User Groups and User Rights
45
Configuring Limitation of Active Power Feed-In
47
Configuring Reactive Power as a Function of Grid Voltage
48
Configuring Modbus Devices
49
Configuring a System with Several Data Managers
50
Speedwire Encryption of the System Communication
51
Switching Digital Outputs Based on Thresholds
52
Activate Licensed Functions
53
Configuring EEBUS Devices
53
Creating and Importing a Backup File
54
Configuring Sunny Tripower CORE2
55
Fallback Behavior
56
Firmware Update
57
Updating the Product Firmware
57
Updating the Firmware of Connected SMA Products
58
Troubleshooting
60
Decommissioning the Product
62
Technical Data
63
Accessories
65
Contact
66
EU Declaration of Conformity
67
Declaration of Conformity
68
Compliance Information
69
SMA DATA MANAGER M Operating Manual (58 pages)
Brand:
SMA
| Category:
Inverter
| Size: 1 MB
Table of Contents
Table of Contents
3
1 Information on this Document
5
Validity
5
Target Group
5
Content and Structure of this Document
5
Levels of Warning Messages
5
Symbols in the Document
6
Typographies in the Document
6
Designation in the Document
6
Additional Information
7
2 Safety
8
Intended Use
8
Important Safety Instructions
8
Supported Products
11
3 Scope of Delivery
13
4 Product Overview
14
Product Description
14
Symbols on the Product
15
Function Button
16
LED Signals
16
Sunny Portal
18
Interfaces and Functions
18
5 Mounting
22
Requirements for Mounting
22
Mounting the Product
23
6 Connection
25
Overview of the Connection Area
25
Preparing the Connection Cable
25
Connecting Signal Source to Digital Input
25
Connecting RS485 Devices
27
Connecting the Voltage Supply
29
7 Commissioning
32
Establishing a Direct Connection Via WLAN
32
Establishing a Connection Via Ethernet in the Local Network
33
Commissioning the Product
34
Registering in Sunny Portal
35
8 Operation
37
Design of the User Interface
37
User Groups and User Rights
38
Configuring Limitation of Active Power Feed-In
39
Configuring Reactive Power as a Function of Grid Voltage
41
Configuring Modbus Devices
42
Configuring a System with Several Data Managers
43
Speedwire Encryption of the System Communication
43
9 Firmware Update
45
Updating the Product Firmware
45
Updating the Firmware of Connected SMA Products
46
10 Troubleshooting
47
11 Technical Data
49
12 Accessories
51
13 Contact
52
14 EU Declaration of Conformity
55
15 Compliance Information
56
Advertisement
SMA DATA MANAGER M Technical Information (22 pages)
SMA Modbus Interface, ennexOS
Brand:
SMA
| Category:
Recording Equipment
| Size: 0 MB
Table of Contents
Table of Contents
3
Information on this Document
4
Validity
4
Target Group
4
Content and Structure of this Document
4
Levels of Warning Messages
4
Symbols in the Document
5
Typographical Elements in the Document
5
Additional Information
5
Safety
6
Intended Use
6
Important Safety Instructions
6
Product Overview
8
Modbus Protocol
8
SMA Modbus Profile
8
System Topology
8
Addressing and Data Transmission
8
Unit Ids
8
Register Address, Register Width and Data Block
8
Data Transmission
8
Reading and Writing of Data
9
SMA Data Types and Nan Values
10
SMA Data Formats
10
SMA Firmware Data Formats
11
Modbus Ports
11
Data Processing and Time Behavior
12
Number Codes of Time Zones
13
Frequently Used Number Codes
16
Configuration
19
Contact
20
Advertisement
Related Products
SMA MD.485-40
SMA MD.485-US-40
SMA MD.IO-40
SMA MD.SEN-40
SMA MD.SEN-US-40
SMA MD.IO-41
SMA MyGen 1500
SMA MyGen 2000
SMA MY 68
SMA MULTICLUSTER-BOX 12
SMA Categories
Inverter
Paint Sprayer
Measuring Instruments
Control Unit
Recording Equipment
More SMA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL