4.6.7
Dashboard
On the dashboard of the user interface, information on the product, the plant and its components is
displayed clearly and at a glance using widgets. The dashboard display can vary depending on
the system's functional scope and user rights.
Information, such as yield forecast, system section visualization and inverter comparison, are
available via the extended functions in Sunny Portal.
4.6.8
Plant-wide parameterization
You can use the system parameter assistant to change the parameters of connected devices at the
same time and to compare them. Simply select the desired devices from a list and change the
parameters that are suitable for simultaneous change. The status of the parameter changes is
accessible at all times.
4.6.9
Energy Monitoring
Several SMA Energy Meters and Modbus energy meters from other manufacturers can be
connected for comprehensive energy monitoring. The product can also read out, save and display
the generation and consumption data of the meters.
In addition, energy meters (e.g. a gas meter) can be registered via the extended functions in
Sunny Portal. The meter readings can be entered manually and displayed.
4.6.10 FTP push
The FTP Push function can be used to upload collected system data to a freely selectable external
FTP server. The collected system data is uploaded to the specified directory hourly or once a day.
Here, the system data is exported in an unchangeable XML format. The system data and user data
is transmitted via standard FTP protocol to the FTP server without encryption.
4.6.11 SMA Smart Connected
SMA Smart Connected is the free monitoring of the connected SMA inverters via the SMA
Sunny Portal. Thanks to SMA Smart Connected, the operator and qualified person will be informed
automatically and proactively about events that occur in the connected SMA inverters.
SMA Smart Connected is activated during registration in Sunny Portal. In order to use SMA Smart
Connected for connected inverters, it is necessary that the product is permanently connected to
Sunny Portal and the data of the operator and qualified person is stored in Sunny Portal and up to
date.
SMA Smart Connected can only be used in Sunny Portal when this feature is supported by the
SMA inverters.
4.6.12 Grid Management Services
The product is equipped with service functions for grid management.
Depending on the requirements of the grid operator, you can activate and configure the functions
(e.g. active power limitation) via operating parameters.