9.4
Parameter changes via the device settings or a
parameter adjustment are not confirmed
Cause
Connected devices do not
send notifications about pa-
rameter changes that were
made.
Parameters are modified by
2 users simultaneously.
9.5

The product cannot be registered in Sunny Portal

Cause
The Internet connection via
a proxy server is not possi-
ble.
The PIC or RID entry is incor-
rect.
9.6
The firmware of a connected SMA product was not
updated during a firmware update
Cause
The firmware version down-
loaded is not the latest or is
not suitable for the SMA
product.
The DC input voltage is not
sufficient for a firmware up-
date.
The transmission quality in
the local network is not suffi-
cient.
Operating manual
Remedy
• Check after about 5 minutes whether the parameter change
has been accepted. If necessary, repeat the parameter change.
• Ensure that parameters cannot be modified at the same time on
the user interface of the product and in Sunny Portal.
Remedy
• Contact your network administrator.
• Verify your entry.
Remedy
• The firmware version must be later than the firmware version
installed on the SMA product. Ensure that you have
downloaded the correct firmware version for your SMA
product and update the firmware again.
• With older inverters, a firmware update is only possible above
a certain DC input voltage. Depending on the time of day, the
weather, and the condition of the PV modules (e.g. affected by
pollution or covered with snow), the DC input voltage may be
too low for a firmware update. Ensure that there is sufficient DC
voltage present and update the firmware again.
• Errors can occur during data transmission if the transmission
quality in the local network is too low. Check the network status
of your local network and, if necessary, contact your network
administrator.
9 Troubleshooting