Field Service Ver. 1.0 Jul. 2005
Code
Item
C1192
Front Aligning Plate
Motor malfunctions
C1193
Rear Aligning Plate
Motor malfunctions
C11A4 Booklet Exit Motor
malfunctions
C11B1 Stapler Unit Slide Motor
malfunctions
• The Front Aligning Plate Home Position Sensor (PI4-FN) is not
unblocked even after the lapse of a given period of time after the
Front Aligning Plate has started moving from its home position to
a position out of the home position.
• The Front Aligning Plate Home Position Sensor (PI4-FN) is not
blocked even after the lapse of a given period of time after the
Front Aligning Plate has started moving from a position out of the
home position to the home position.
• The Rear Aligning Plate Home Position Sensor (PI5-FN) is not
unblocked even after the lapse of a given period of time after the
Rear Aligning Plate has started moving from its home position to
a position out of the home position.
• The Rear Aligning Plate Home Position Sensor (PI5-FN) is not
blocked even after the lapse of a given period of time after the
Rear Aligning Plate has started moving from a position out of the
home position to the home position.
• The Exit Belt Home Position Sensor (PI7-FN) is not unblocked
even after the lapse of a given period of time after the Booklet
Exit Belt has started moving from its home position during an ini-
tial operation.
• The Exit Belt Home Position Sensor (PI7-FN) is not unblocked
even after the lapse of a given period of time after the Booklet
Exit Belt has started moving from its home position during an
ordinary operation.
• The Exit Belt Home Position Sensor (PI7-FN) is not blocked even
after the lapse of a given period of time after the Booklet Exit Belt
has started moving from a position not the home position during
an initial operation.
• The Exit Belt Home Position Sensor (PI7-FN) is not blocked even
after the lapse of a given period of time after the Booklet Exit Belt
has started moving from a position not the home position during
an ordinary operation.
• The Slide Home Position Sensor (PI18-FN) is not unblocked
even after the lapse of a given period of time after the Stapler
Unit has started moving from its home position.
• The Slide Home Position Sensor (PI18-FN) is not blocked even
after the lapse of a given period of time after the Stapler Unit has
started moving from a position not the home position.