Customer Display Interface

Symptoms: The Integrated or Pole Customer Display does not function. The
unit should auto-detect the LCD or IEE 2x20 VFD customer display at
power-up. If a customer display is not detected after several power-up cycles,
you can check the following.
Internal customer display cable disconnected from J2 or IO panel
connector damaged.
Damaged Pole Customer Display Connector CN4.
No Power to Customer Display Connector.
Make sure +5V appears at J2-1. If not, check voltage switch Q27, Q15
o
and F2.
Defective Interface circuit.
Multiplexer U10, NOR Gate U4A and U4C, and Level Shifter U3.
o