Comtech EF Data SDM-9000 Installation And Operation Manual page 179

Table of Contents

Advertisement

SDM-9000 Satellite Modem
BER THRESHOLD
MODULE
PROGRAMMING
CONFIGURATION
Rev. 4
The preset BER threshold has been exceeded.
Setting of this alarm is done in the Configuration menu. This is an
alarm based on the corrected BER reading on the front panel.
Demodulator module fault.
Typically indicates that the demodulator module is missing or will
not program. Ensure the demodulator card is present and
properly seated. If the card is properly seated, this could indicate
a problem in the M&C card, or in the interface between the
demodulator card and the M&C card. Return the defective card
for repair.
Demodulator programming fault.
Indicates the demodulator module has failed to program a
current configuration parameter. If this fault occurs, contact
EFData Customer Support assistance.
Demodulator configuration fault.
Indicates the demodulator module does not support a
programmed configuration parameter. This fault typically occurs
when the programmed configuration does not match the module
hardware. Verify the programming of the demodulator hardware
matches the configuration parameters.