Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Use a tie wrap to secure the wires to the rack, so that the wires are not pulled from the terminal block
Step 10
plug by casual contact. Make sure the tie wrap allows for some slack in the ground wire as shown in
Figure
Figure 14-87
1
Step 11
Make certain the terminal block plug is fully seated in the terminal block header on the DC power supply
panel. You will hear a snap or click when installed properly.
Remove the tape (if any) from the circuit-breaker switch handle and move the circuit-breaker switch
Step 12
handle to the on position.
On the rear of the router, place the power supply Standby switch in the on position (O) to turn on the
Step 13
router.
The power supply LEDs light when power is supplied to the router.
This completes the procedure for connecting the DC power supply in the Cisco ASR 1001 Router.
Removing DC Input Power from the Cisco ASR 1001 Router
This section describes how to remove a DC power supply from the Cisco ASR 1001 Router. Follow these
steps:
Turn off the circuit breaker.
Step 1
On the rear of the chassis, place the Standby switch in the Standby position (|).
Step 2
Pull the terminal block plug connector out of the terminal block head in the power supply.
Step 3
Unscrew the two power supply fasteners on the unit.
Step 4
OL-13208-11
14-87.
Complete DC Terminal Block Plug Insertion and Secure Tie Wrap
Lead wires secured with a tie wrap
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
Removing and Replacing the Cisco ASR 1001 Router Power Supplies
1
2
2
DC power supply terminal block plug being
inserted into terminal block header.
14-113