Connecting Power to the Cisco ASR 1006 Router
b.
Attach the other end of the cable to the site's ground connection.
Step 3
Remove the plastic cover from the terminal block.
Step 4
Before you continue to install the terminal block ground wires, stop and perform Step 5. To prevent any
Caution
contact with metal lead on the ground wire and the plastic cover.
Step 5
Wrap the positive and negative lead cables with sleeving. Take each lead wire and cover the area from
the lug to the wire with heavy shrink sleeving.
Figure 6-21
Figure 6-21
Cisco ASR 1006 Router DC Power Supply (ASR1006-PWR-DC) Terminal Block Ground Cable Lugs
1
2
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
6-30
Grounding cable lug
–
Kepnut screw
–
Tighten the Kepnut screws on the power supply studs.
shows the ASR1006-PWR-DC power supply for the Cisco ASR 1006 Router.
This unit might have more than one power supply connection. All connections must be removed to de-energ
4
Negative lug and wire with sleeving wrapped
around the wire and end of lug
Positive lug and wire with sleeving wrapped
around the wire and end of lug
Chapter 6
1
2
-48/-60V
40A
3
3
Location of sleeving wrapped around the wire
and end of the grounding stud
4
Ground lug and wire
Cisco ASR 1006 Router Overview and Installation
OL-13208-11