Cisco ASR 1000 series Hardware Installation Manual page 531

Aggregation services routers
Table of Contents

Advertisement

Chapter 14
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Figure 14-74
Figure 14-74
1
2
Replace the terminal block plastic cover, which is slotted and keyed to fit correctly over the terminal
Step 11
block; then tighten the black screw (use the screwdriver to tighten the screw to a torque of 5 in-lbs / 1
per.).
Remove the tape from the circuit-breaker On/Off switch (if there was any).
Step 12
Step 13
Switch the circuit breaker On/Off switch to the On (|) position.
The requirement for maximum torque applied to the power or ground Kepnuts must be 8 in-lb when the
Note
power or ground lug is not present.
This completes the procedure for installing the DC power supply into the Cisco ASR 1013 Router.
Removing and Replacing the Cisco ASR 1001 Router Power
Supplies
The Cisco ASR 1001 Router AC and DC power supplies are shipped installed in the chassis. You must
connect the power supplies when they arrive.
The Cisco ASR 1001 Router can support either two AC or two DC power supplies. Do not mix the AC
Note
and DC power supply units in the same chassis.
OL-13208-11
shows the DC power supply terminal block with cables connected.
Cisco ASR 1013 Router DC Power Supply Terminal Block Cable Connections
-48/-60V
This unit might have more than one power supply connection. All connections must be removed to de-energize the unit.
4
Negative lead
Positive lead
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
Removing and Replacing the Cisco ASR 1001 Router Power Supplies
1
2
40A
3
3
Protective sleeving around the stud and cable
4
Ground stud and cable
OUTPUT INPUT
FAN
FAIL
OK
OK
ALARMS
60V
1A MAX