Removing and Replacing Cisco ASR 1000 Router eUSB Devices
Figure 14-30
1
1
Cisco ASR 1000 Series RP eUSB device Phillips screw
Gently pull the eUSB device up from its connector and remove it.
h.
Place the eUSB device in an antistatic bag for return.
i.
You have removed the Cisco ASR1000-RP and eUSB component.
To replace the eUSB component, follow these steps:
Align the replacement eUSB device over the connector and standoff. The device fits over the threaded
Step 1
post that sticks up off the board and accepts a screw to hold the eUSB firmly to the Cisco ASR 1000
Series RP board.
Step 2
Gently insert the new eUSB device by pressing it into the connector keeping aligned with the standoff
and secure the eUSB device with the small Phillips screw as displayed in
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
14-40
Chapter 14
Cisco ASR1000-RP eUSB Device
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers