Removing and Replacing the Cisco ASR 1013 Router Power Supplies
Turn the power supply standby switch to the Standby position. See
Step 3
Figure 14-69
Cisco ASR 1013 Router AC Power Inlet and Standby Switch
5
4
1
2
3
4
5
*For information about the DB-25 alarm connector, how it works, and Cisco ASR 1000 series route processor LEDs, see the
Note: Shielded cables must be used to connect to the DB-25 alarm connector on both the AC and DC power supplies, in order
Step 4
Unplug the power cable from the AC inlet on the back of the power supply and the power source.
Step 5
Unscrew the power supply captive screws.
Note
If you remove a power supply, the system can run for a maximum of five minutes before the system shuts
Caution
down. The fans and power elements are independent within the power supply. Therefore, it is not
required that the replacement power supply be energized within five minutes. The only requirement is
that the power supply be installed in the chassis, which energizes the fans and maintains proper system
cooling.
Grasping the power supply handles, pull the power supply from the chassis.
Step 6
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
14-94
6
7
8
100-240V~ 16-7A
50-60HZ
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
3
AC power supply fan
DB-25 alarm connector*
Cable tie wrap tabs
AC power supply captive screws
AC power supply handle
"How Cisco ASR1000-RP Alarm Monitoring Works" section on page
to comply with FCC/EN55022/CISPR22 Class A emissions requirements.
The Cisco ASR 1013 router has two power zones, each containing two power supplies for a
redundant system. Power supplies must be installed in the chassis at all times to ensure sufficient
cooling. The system fans are inside the power supply units and must spin for cooling. Because
all the system fans can be powered by one power supply, the second power supply unit does not
have to be powered on, but it must be installed.
Chapter 14
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
9
OUTPUT INPUT INPUT
FAIL
OK
OK
ALARMS
60V
1A MAX
2
6
AC power inlet
7
AC power supply standby switch. A standby switch is
not considered a disconnect.
8
Protective sides around the standby switch
9
AC power supply LEDs
2-20.