Preparation
§ Turn on the scale: Press e/[ON/OFF]
> Sartorius logo is displayed, self-test is performed
§ Select the "Time-controlled functions" application in the Setup menu:
Press M
§ Select the Application menu:
§ Select
Application 2
O soft key
§ Select
Time-controlled functions
§ Confirm
Time-controlled functions
§ Select and confirm:
Function after time interval
or
Beep
Lock in readout
Automatic printout of values
Store value in applicat. 3 memory
Automatic function restart
or
On
Off
:
Storage mode
Without stability
After stability
After higher stability
Print then tare
or
Off
On
see also the "Application Menu (Overview)" in the chapter entitled
"Configuring the Scale"
§ Save settings and exit the Setup menu: Press M
Print Net Values without Printout of Time
Configuration settings:
Setup: App: Basic settings: Printout configuration: Auto. at init.: Off
66
soft key
App
: Press the q soft key and then the
: Q or q soft key
: O soft key
:
or
or
:
or
or
:
Additional Functions
In addition to the functions for:
– alphanumeric input,
– taring (not during alphanumeric
input),
– printing,
you can also access the following
functions from this application:
– calibration (not during alpha-
numeric input or initialization),
– toggling to another application
(e.g., counting),
– setup,
– turning off the scale.
Calibration/Adjustment
§ Press the
soft key
isoTST
> See "Calibration/Adjustment"
for further instructions
Toggling to Another Application
§ Press D/[TOGGLE]
> See the section on the
corresponding application
program for further instructions
Setup (setting parameters)
§ Press M
> See "Configuring the Scale"
for further instructions
Turning Off the Scale
§ Press e/[ON/OFF]
> The scale shuts off
> The display goes blank

Hide quick links: