RS232/RS485 Communication Port and IP (DIP Switch) Settings
RS232/RS485
Communication Port,
and DIP Switch
(1) DIP Switch Default: RS232, ID=1
(2) DIP Switch Setting: The default of DIP Switch is "OFF" which locates at the ID display side.
Shit to the other side to turn the DIP Switch "ON."
Options for Communication Ports
Comm. Port
RS-232
RS-485
Note: NO.1 and NO.2 can not be turned on at the same time; i.e. RS-232 and RS-485 can not be is
use concurrently.
(1) NO.3 ~ NO.8 are node ID (a binary system)
(2) If NO.3 is ON and others are OFF, it means 01.
(3) If NO.4 is ON and others are OFF, it means 02.
(4) If NO.5 is ON and others are OFF, it means 04.
(5) If NO.6 is ON and others are OFF, it means 08.
(6) If NO.7 is ON and others are OFF, it means 16.
(7) If NO.8 is ON and others are OFF, it means 32.
Example
If node ID is 1, the DIP Switch setting should be NO.3 is ON and others are OFF.
If node ID is 3, the DIP Switch setting should be NO.3 and NO.4 are ON, and others are
OFF.
If node ID is 5, the DIP Switch setting should be NO.3 and NO.5 are ON, and NO.4 and
others are OFF.
If node ID is 7, the DIP Switch setting should be NO.3~NO.5 are ON, and NO.6 ~ NO.8
are OFF.
The Node ID is the sum of DIP Switch NO.3 to NO.8.