IOB-0805 BOX Guide
Technical Specification
Digital Contact Input
Isolation
Digital Level 0
Digital Level 1
Relay Output
Relay Type
Contact Rating
Operate Time
Release Time
Dielectric Strength
Electrical life(min.)
Mechanical life(min.)
Power Consumption
Communication Port
Communication Distance
Input Power Supply
Dimension
Weight
Approved Standards
CE
8
5000Vrms
Open
Close
5
Form A
10A@125VAC, 5A@250VAC/30VDC
8 ms
5 ms
2500VAC
5
1 x 10
7
1 x 10
110 / 220 VAC or 5VDC, 5W¡C
RS232 / RS485 (Protocol : Huper RTU ASCII)
RS232:1200 – 115, 200 bps; RS485 : 1200 – 921.6K bps
RS232: 50 feet
RS485: 4000 feet
110 / 220 VAC or 5VDC, Digital Input¡G 5/12/24 VDC
150 x 100 x 40 mm
360 g
CE
Approved