Settings Pages
Sensor Settings Page
Motion Detection:
Wake Panel on Motion Sense: Click this button to wake up the panel if any motion detected crosses the threshold set
Wake Panel on Motion Test:
Light Sensor Dim Mode:
Light Sensor Level:
Light Sensor Calibration:
Light Sensor Level Port:
Light Sensor Level:
Light Sensor Channel Port:
Light Sensor Channel:
Motion Sensor Channel Port:
Motion Sensor Channel:
Sensor Version:
Light and motion sensor ports, levels, and channels are configured in TPDesign4. For
more information on configuring light and motion sensors, please refer to the
TPDesign4 Operation/Reference Guide, available at www.amx.com.

Calibrating the Light Sensor

When the touch panel is installed for the first time, the light sensor should be calibrated to the room's maximum ambient
light condition. This calibration setting will be saved until the panel's system settings are reset (for more information,
please refer to the Panel Configuration on page 24).
To calibrate the light sensor from the Settings pages:
1.
From the Sensor Settings page, click the Light Sensor Calibration button.
2.
Give the panel 10 seconds to calibrate the room's ambient light level. The indicator next to the button will flash
green while calibration is in progress.
If necessary, the touch panel light calibration may also be done remotely through a Telnet connection. To calibrate the
light sensor via Telnet:
1.
Telnet into the touch panel.
2.
Type "light cal 1".
3.
Give the panel 10 seconds to calibrate the room's ambient light level.

Function Show Example

When the Function Show feature is displayed, the Channel Port and Code will appear in yellow, the Address Port and
Code in blue, and the Level Port and Code in purple (FIG. 44).
28
• The yellow indicator shows the current motion sensor reading.
• The movable circle sets the motion sensor threshold.The threshold controls when a
motion sensor channel is on.
• The "walk" icon with also change color from grey to green when the threshold is
crossed.
by the Motion Detection slider.
This button will only be enabled if Wake Panel On Motion Sense is enabled.
Pressing the test button will initiate a test mode where the display will go to sleep and
wait for motion to turn it on. It can be used to test your current Motion Detection
threshold value.
Click this button to set the light sensor for dim lighting conditions.
• The yellow indicator displays the current light sensor reading.
• The movable circle indicates the light sensor threshold.
• The threshold controls when a Light Sensor Channel Code press will be generated.
Click this button to perform a calibration on the light sensor.
This displays the current level port being used by the light sensor (default = 1).
This displays the current level being used by the light sensor (default = 0).
This displays the current channel port being used by the light sensor (default = 1).
This displays the current channel being used by the light sensor (default = 0).
This displays the current channel port being used by the motion sensor (default = 1)..
This displays the current channel being used by the motion sensor (default = 0).
This displays the current sensor version, if applicable.