Sensors page options
Motion Detection:
Wake on Motion Sense:
Wake on Motion Test:
Light Sensor Level Value:
Light Sensor Calibration:
Light Sensor Level Port:
Light Sensor Level Number:
Light Sensor Channel Port:
Light Sensor Channel Number:
Motion Sensor Channel Port:
Motion Sensor Channel Number: This displays the current channel being used by the motion sensor. The default is 0.
Sensor Version:
Light and motion sensor ports, levels, and channels are configured in TPDesign 5.
For more information on configuring light and motion sensors, please refer to the
TPDesign 5 Operation/Reference Guide, available at www.amx.com.

Calibrating the Light Sensor

When the touch panel is installed for the first time, the light sensor should be calibrated to the room's maximum ambient
light condition. This calibration setting will be saved until the panel's system settings are reset.
To calibrate the light sensor from the Settings pages:
1.
From the Sensor Settings page, click the Light Sensor Calibration selection.
2.
Give the panel 10 seconds to calibrate the room's ambient light level. The indicator next to the button will run a
rotating circle while calibration is in progress.
Modero G5 Touch Panels - Configuration and Programming
• The blue bar within the slide bar shows the current motion sensor reading.
• The slide bar sets the motion sensor threshold.The threshold controls when a
motion sensor channel is on.
• The "walk" icon shows bars on either side when the threshold is crossed (FIG. 30).
Click this checkbox to wake up the panel if any motion detected crosses the threshold
set by the Motion Detection slide bar.
This selection only be enabled if Wake Panel On Motion Sense is enabled.
Pressing the test button will initiate a test mode where the display will go to sleep and
wait for motion to turn it on.
It can be used to test your current Motion Detection threshold value.
• The blue bar within the slide bar displays the current light sensor reading.
• The slide bar indicates the light sensor threshold.
• The threshold controls when a Light Sensor Channel Code press will be generated.
Click this button to perform a calibration on the light sensor.
This displays the current level port being used by the light sensor. The default is 1.
This displays the current level being used by the light sensor. The default is 0.
This displays the current channel port being used by the light sensor. The default is 1.
This displays the current channel being used by the light sensor. The default is 0.
This displays the current channel port being used by the motion sensor.
The default is 1.
This displays the current sensor version, if applicable.