Selecting the
Lamp Type Menu
The display shows in 10
sections names of manu-
factures. MORE turns the
page for more manufac-
tures. The list in the
centre shows the 16
selected lamp types.
For self-defined scans
!
please choose "User
Scan" (see chap. 11). You
can call 16 different scans
which were defined by
yourself previously.
Selecting number of Scans
Selecting manufacturer and

lamp type

Registration of selected
lamp type
8 8 8 8 8
MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de
2.2 Lamp type
The MA SCANCOMMANDER is able to control various lamp types. All necessary
adjustments are made by simply choosing a lamp type from the list.
SETUP
LAMPTYPE
CLAY PAKY
CAMELEON
FRANCE
B + K
GERMANY
AMPTOWN
GERMANY
USER SCAN
MORE
1(3)
SELECT TYPE
Manufacturer Name
Encoder 1:
READY
INIT:SCANS+VALUES+NAMES
The button on top of the display label "SETUP"
switches the board to the setup menu.
COEMAR
ITALY
ITALY
LAMPTYPE SETUP
1 GOLD 2
9 GOLD 2
10 GOLD 2
2 GOLD 2
3
GOLD 2
11 TIGER
4
GOLD 2
12 TIGER
13 INTEL7
5
GOLD 2
6 GOLD 2
14 INTEL7
7 GOLD 2
15 INTEL7
8 GOLD 2
16 INTEL7
GOLDEN SCAN 2
In the "Scan Selection" block the buttons have to be
switched on according the number of scans to be
registered.
When pushing the desired button, the square of that
manufacturer will be shown inverted.
In the lower section of the display you find the first
types of fixtures of the selected manufacturer. Turn-
ing Encoder 1 will scroll through the list of available
lamps. If there are "Presets" for the chosen type the
scan type will be shown inversely.
After selecting the desired lamp type, press READY
All necessary data for this scan type is now
downloaded. The three other kinds of initialization are
for registration of different scan types for simultane-
ous operation.
FAL
ITALY
FLY
ITALY
JB
GERMANY
LAMPO
ITALY
READY