Lightcommander 24/6 - 48/6 0.2 Specifications and Installation The MA Lightcommander II is available in two versions: 24/6 and 48/6. Both versions have a 100 - 240 Volt AC input on the back panel. The signal outputs to your dimmers are: DMX 512 (1990) and 30 / 54 channel analog via Socapex EF337.
Page 6
MEMORY 13-16, in case of Chase on Memory Page 29 PREVIEW CHASE IN MEMORY LEARN STEP SOUND 6 6 6 6 6 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de...
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 1.3 Extra Channels (AUX 1-6) Beside the 24 rsp. 48 channels of the presets the Lightcommander II offers six additional channels via the potentiometers AUX 1 to AUX 6. Adjust- ments on this pots are independent from the Main Master, Blackout button or Preset Masters and are specially designed for the control of colour changers or other stage effects.
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 3. Chaser Programs Beside the static memories it is possible to store up to 50 chaser effects with up to 99 steps each. There are three different kind of chase programs regarding the way of setting the steps: ON-OFF Chase: on each step a selection of channels is switched on to 100%.
Going on with setting channels and Enter will add additional steps. The QUIT button switches back to the TOP MENU. 14 14 14 14 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de...
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 3.2 Programming Real-Level Chases On Real-Level Chases the single channels can have freely adjusted values for each step. Programming works like with the ON-OFF chases but LEVEL has to be selected via the CHASE button.
The adjusted speed, the mode and the fadetime is stored together with the chase number. 16 16 16 16 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de...
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 3.6 Controlling the Fade between Chase Steps The change between steps of a chase can be preformed as switching to the new values or as a slow fade.
While the SPEED button is pressed, the Encoder changes the chaser speed. Quit returns the desk to the Top Menu. 18 18 18 18 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de...
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 4. Dipless Crossfade (X-Fade) Right hand of the memory master faders the Lightcommander offers a special X-Fade section for dipless crossfades between stage scenes. Unlike the effect of changing from one memory to another by moving up or down the faders, on dipless X-fades any channel changes linearly to its new value.
While the "X-Fade On/Off" button is held down, the X-fade mode can be terminated by the display buttons SWITCH OFF or FADE OFF. 20 20 20 20 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de...
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 4.2 Manual Crossfades between Memories Instead of fading automatically with adjusted times it is possible to fade manually by moving the X-fader ...
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 5. Preprogrammed Lighting Shows (Sequences) Beside the chaser programs there are another 50 sequence programs to be stored and recalled on the X-fade section exclusively. Compared to the chaser programs this sequences may have preprogrammed times per step and may recall a chase as one of the steps.
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 6. Preview and Modifying Any program of the Lightcommander can be previewed and modified before it comes to stage. The actual output values can be listed in per- centage and the Limit function enables to reduce the overall brightness of any channel.
The PREVIEW or QUIT button returns the board to the Top Menu. Any limitation gets indicated by the warning "OUTPUT LIMIT". 26 26 26 26 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de...
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 6.4 Previewing and Modification of Memories Previewing a memory: PREVIEW button Any memory flash button The LED´s show the channel values as stored in the memory.
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 6.6 Previewing a Chase 6.6.1 Preview at the Chaser Section Chases store the speed and fade time of their last recall. Before starting with the ON button, the program and its times can be previewed and modified.
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 6.7.2 Modifying X-Fade Steps By using PREVIEW - X-FADE the intensity of the single channels can be modified for any of the steps. Modifying REAL LEVEL steps: STEP 06 CHASE --...
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 7. Special Functions UTILITY/SETUP menus of the Lightcommander offer various spe- cial functions and setup facilities. 7.1 Single Channel Setups 7.1.1 Doubling the Channel Number (WIDE Function) One of the most interesting features of software version 2.X is the possibi- lity to double the number of channels.
During WIDE operation the patch command "1 : 1" will patch the AUX channels at the end of the standard channel range (LC24: 49-54, LC48: 97-102). 34 34 34 34 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de...
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 7.1.3 Dimmer Curve Standard dimmerpacks usually show an non-linear increase on brightness when moving up the channel fader. By choosing a special non-linear output modulation this effect can be compensated.
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 7.2.3. Theatre Sequence There are two special modi for Theatre Sequences available with only a little difference. In general every sequence receives within both modi a step name consisting of numbers instead of a step number.
SETUP Within the setup menu time and date can SETUP be adjusted via encoder 38 38 38 38 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de...
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 7.7 HOLD Function The HOLD function will freeze the output of the desk. Changes can then be made on the desk without those changes occuring on the stage. When ready, those changes can be output from the desk by reducing the main master to 0, and than back to 100 %.
For the exact format of used MIDI com- mands see the following list. 40 40 40 40 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de...
Page 41
Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander 24/6 - 48/6 Lightcommander II 24/6 + 48/6 MIDI Codes The Lightcommander uses Control Change Data exclusively. Within the MIDI menu two different sets of control orders can be chosen, To avoid coincidences, either one or the other can be used.
If the Socapex output is not in use, please put the enclosed plastic cap on it; so no electrostatic discharging can happen within the plugs. 42 42 42 42 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de...
14. Only use wires which are marked safety proof. 15. Don´t use any high-power walkie-talkies near the unit. 46 46 46 46 MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . Fax: + 49 9 31 4 97 94 29 . www.malighting.de...
MA Lighting Technology GmbH Address of producer: Dachdeckerstr. 16 D-97297 Waldbüttelbrunn Germany declares that the product Name of product: MA Lightcommander 24/6 and 48/6 Type: LC 24/6 and LC 48/6 answers the following product specifications: Safety: EN60065, resp. EN60965 EMV (EMC):...
Page 48
Lightcommander 24/6 - 48/6 User's Manual User's Manual User's Manual User's Manual User's Manual V V V V V ersion 2.59 ersion 2.59 ersion 2.59 ersion 2.59 ersion 2.59...
Need help?
Do you have a question about the LIGHTCOMMANDER II 24/6 and is the answer not in the manual?
Questions and answers