Finishing Work And Cleaning - WAGNER GA 2000EAC Translation Of The Original Operating Manual

Electrostatic aircoat spray gun for automatic operating mode with fl at or round jet nozzles
Table of Contents

Advertisement

EDITION 12/ 2008
OPERATING MANUAL
6.1

FINISHING WORK AND CLEANING

Exploding gas/ air mixture!
Danger to life from flying parts and burns
SIHI_0008_GB
1. Switch off control unit.
2. Relieve spray gun and unit pressure.
3. Replace material by cleansing agent.
4. Turn off air supply to the gun (on the EPG 3000 turn the air regulator to zero).
Note:
➞ If the round jet nozzle is fi tted: By means of nozzle spanner (A), loosen nozzle insert (B)
by a half turn.
➞ If the fl at jet nozzle is fi tted: Remove and clean the AirCoat nozzle
5. Thoroughly fl ush spray gun.
6. Relieve spray gun and unit pressure !
7. Clean the body of the gun with solvent which has been recommended by the paint
manufacturer and dry with a cloth or blow gun.
Cleaning agent in the air duct!
Functional faults caused by swollen seals
Always point the spray gun down when cleaning.
Ensure that neither paint nor cleaning agent enters the air duct.
SIHI_0005_GB
The gun attachment (X) may only be changed by the
WAGNER Service Station.
PART NO. 350741
Never spray into a closed container.
Earth the container.
CAUTION
DANGER
GA 2000EAC, GA 2005EAC
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ga 2005eac

Table of Contents