Finishing Work And Cleaning - WAGNER GM 4600AC Operating Instructions Manual

Aircoat
Table of Contents

Advertisement

EDITION 02/2008
OPERATING MANUAL
6.1

FINISHING WORK AND CLEANING

Exploding gas/ air mixture!
Danger to life from flying parts and burns
SIHI_0008_GB
Cleaning agent in the air duct!
Functional faults caused by swollen seals
Always point the spray gun down when cleaning.
Ensure that neither paint nor cleaning agent enters the air duct.
SIHI_0005_GB
Note:
Methylene chloride is not recommended as a fl ushing or cleaning solvent with this gun or
any system components.
1. Relieve spray gun and unit pressure.
2. Secure gun with trigger safety catch.
3. Connect cleaning supply.
4. Remove AirCoat jet nozzle and clean separately (see chapter 5.4.3).
5. Pressurize the cleaning supply to approx. 4 MPa; 40 bar; 580 psi and thoroughly fl ush
the spray gun.
6. Relieve spray gun and unit pressure.
7. Secure gun with trigger safety catch.
8. Clean gun body with a cleaning agent recommended by the manufacturer, and dry
with a cloth.
Part No. DOC394861
Never spray into a closed container.
Earth the container.
CAUTION
DANGER
GM 4600AC
25