REMOVE AND REPLACE FUEL PUMP FLEXIBLE COUPLING
INITIAL SETUP:
Tools and Special Tools
General Mechanics Tool Kit
Materials/Parts
Drain Pan or Bucket
Rags
REMOVAL OF FLEXIBLE COUPLING:
1. Remove the fuel pump/solenoid as follows:
a. Disconnect power cord from power supply.
b. Attach drain hose to the fuel water separator bowl drain valve.
c. Open drain valve and drain contents into a waste fuel container.
d. Using a 9/16" open end wrench, loosen and disconnect fuel in-line at fuel water strainer housing.
e. Remove drain hose and retighten drain valve.
f.
Using a 9/16" open end wrench, loosen and disconnect fuel line at the fuel pump/solenoid assembly.
g. Using a 7/16" open end wrench, loosen and disconnect the fuel nozzle tube.
h. Disconnect the solenoid electrical harness plug.
i.
Using a ½" open end wrench, loosen and remove the fuel pump/solenoid assembly (2) mounting
bolts.
j.
Remove fuel pump/solenoid assembly from burner motor housing.
k. Remove the flexible coupler from the fuel pump/solenoid shaft.
Part Number: 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
G2 Series Decontamination Water Heater
PROCEDURES REQUIRE VERIFICATION
References
Equipment Condition
Equipment Powered Down
Power Source Disconnected
0015-9
WORK INPROGRESS
DHS Systems LLC
0015

Advertisement

Table of Contents
loading

This manual is also suitable for:

G2sG2s-i

Table of Contents