INSPECTION AND CLEANING SUCTION TUBE SCREEN PROCEDURES (G2S-I ONLY)
INITIAL SETUP:
Tools and Special Tools
General Mechanics Tool Kit
Materials/Parts
Clean Water
INSPECTION OF SUCTION TUBE SCREEN:
1. Disconnect power cord from power supply
2. Remove suction hose from solution tank.
3. If necessary, loosen and remove suction hose from the lower end of the injector assembly.
4. Slide screen off of suction hose and inspect screen for foreign objects.
CLEANING SUCTION TUBE SCREEN:
5. Clean screen by running clean water backwards through screen.
6. Inspect screen for damages; if necessary replace with a new screen.
7. If unable to clean screen thoroughly, replace with new screen..
REINSTALLATION OF SUCTION TUBE SCREEN:
8. Slide screen back onto suction tube.
9. Reconnect and tighten suction hose on the lower end of the injector assembly.
10. Place suction tube assembly into the solution tank.
11. Reconnect power cord into the power supply.
END OF TASK
Part Number: 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
G2 Series Decontamination Water Heater
PROCEDURES REQUIRE VERIFICATION
Personnel Required
One
Equipment Condition
Equipment Powered Down
Power Source Disconnected
0015-18