INSTALLATION OF THE FUEL NOZZLE AND ELECTRODE ASSEMBLY (CONT):
f.
Install and tighten splined nut using a splined wrench.
g. Using a 7/16" open end wrench, reconnect and tighten the fuel nozzle tube B-nut.
2. Installing the electronic igniter assembly as follows:
a. Place the electronic igniter and base plate assembly onto the burner motor housing.
b. Using the following sequence, reconnect the igniter wire harness as follows:
1. Reconnect the igniter blue wire to the black #011 main harness wire to the black wire oil burner
wire harness. Twist the three wires together and install a wire nut.
2. Reconnect the igniter white wire to (3) white wires (one from the main wire harness, one from the
oil burner motor and one from the fuel solenoid plug). Twist wires together and install a wire nut.
c. Crimp all wire nuts for added security.
d. Ensure igniter springs make contact with the insulators.
e. Using a 5/16" open end wrench, install and tighten (2) mounting screws on the top to secure the
electronic igniter and base plate assembly.
f.
Using a cross-point screwdriver, install and tighten (2) screws on the bottom to secure the electronic
igniter and base plate assembly.
g. Reconnect the power cord into power supply outlet.
h. Perform operations and leak checks.
END OF TASK
Part Number: 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
G2 Series Decontamination Water Heater
0015-15
0015
DHS Systems LLC

Advertisement

Table of Contents
loading

This manual is also suitable for:

G2sG2s-i

Table of Contents