DECON SOLUTION INJECTOR OPERATION (CONT)
CHANGING FEED RATE
The feed rate on the injector is adjustable, even while operating and under pressure. Rotate the Ratio Adjustment
Sleeve, clockwise (CW) to decrease and counter-clockwise (CCW) to increase (see Figure 1), to change the Decon
solution ratio. The setting indicator mark indicates the approximate ratio of injection setting. Check the Decon
discharge outlet to assure desired feed rate is being delivered.
Do not rotate the Ratio Adjustment Sleeve below the lowest setting line on
decal. This can cause the injector to lock.
END OF TASK
END OF WORK PACKAGE
Part Number 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
G2 Series Decontamination Water Heater
Ratio Adjusting Sleeve
Figure 1. Ratio Adjustment Sleeve and Bypass Lever.
NOTE
0007-4
0007