DECON SOLUTION INJECTOR OPERATION (G2-I AND G2S-I WATER HEATER ONLY)
The entire water line down stream from the injector will have chemical solution
injected into it. If the chemical solution injected makes the water unsafe to
drink, label the water line.
Avoid a potentially hazardous chemical accident: An injector location should
be selected to provide a safe, but accessible, place for the chemical solution
tank. It should be kept away from high usage areas and meets all applicable
local codes.
Avoid solution contamination: Use only clean FILTERED water. Do not allow
contaminates to enter the Decon solution tank because they will be pumped
into the water line, and can cause the spread of disease and can also cause
excessive wear.
You may use any size Decon solution tank, but it is recommended using one
with a lid or cover.
1. Fill the tank with a Decon solution.
2. Connect or immerse the injector solution hose and filter into the Decon solution tank at least two inches from the
bottom of the tank.
3. Ensure to cover injector solution hose and filter with at least two inches of Decon solution.
4. Follow the start-up procedures in the beginning of this WP. Turn the water heater power ON/OFF switch to the ON
position and begin flowing heated water to the sinks, spray wands or showerheads.
5. Once the water heater is running and the solution has been filled, place the bypass lever (on top of the injector
assembly) to the ON position to activate the injector. (See Figure 1)
When solution is flowing through the injector, a "clicking" sound will be heard.
The higher the flow rate the more frequent the clicking sound will be heard.
See Changing the Feed Rate on page 4 of this WP.
6. When the injector is operating, Decon solution will be drawn from the Decon solution tank and a "clicking" sound
will be heard.
7. When finished using the Decon solution, siphon clean water through the system to flush the Decon solution.
8. When finished flushing the injector system, place the bypass lever into the OFF position.
Part Number 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.