Reeves G2 series Operation Manual page 49

G2 series decontamination water heater
Hide thumbs Also See for G2 series:
Table of Contents

Advertisement

Operation & Maintenance w/IPB
ITEM
CONDITION/INDICATION
2.
Burner will not ignite
(Cont)
(Cont)
3.
Burner motor will not run.
4.
Burner runs erratically.
Part Number: 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
G2 Series Decontamination Water Heater
Table 1. Operator Troubleshooting – Mechanical (Cont).
POSSIBLE MALFUNCTION
Dirty or clogged fuel nozzles.
Improper burner air
adjustment.
Electronic Ignition failure
Ignition electrodes not set
properly, damaged or worn.
Flow switch not completing
fuel solenoid circuit.
Power switch is not in the
"ON" position.
Defective switch
Out of fuel.
Temperature is above normal
operating temperature
Low on fuel.
Contaminated fuel supply and
system.
Contaminated fuel filter.
Dirty fuel nozzles.
Improper air adjustment
setting.
Fuel Pump malfunctioning.
Remove and replace with new nozzle.
Check fuel filter and fuel quality.
Drain and clean entire fuel system, if
required.
Adjust accordingly to the procedures
listed in Maintenance every 3 months.
Remove and replace electronic
ignition.
Replace or adjust accordingly to the
procedures listed in Maintenance
Check for proper flow through heater.
Remove and replace flow switch if
necessary
Contact REEVES EMS.
Turn to "ON" position.
Remove and replace switch.
Refuel.
Unit will automatically reignite after
some cool down time.
Refuel.
Service entire fuel system.
Remove and replace fuel filter.
Replace.
Adjust accordingly to the procedures
listed in Maintenance every 3 months.
Check output pressure.
Remove and replace fuel pump if
necessary.
0010-3
CORRECTIVE ACTION
DHS Systems LLC
0010