Table 1. Operator Preventive Maintenance Checks and Service (Cont).
ITEM
INTERVAL
NO.
5
BEFORE
6
BEFORE
7
BEFORE
8
BEFORE
9
3 MONTH
(TO
INCLUDE
ALL
BEFORE
ITEMS)
Part Number: 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
G2 Series Decontamination Water Heater
ITEM TO BE
CHECKED
OR SERVICED
INJECTOR
ASSY (G2-I
AND G2S-I
Only)
Injector Inlet
Visually inspect filter for cleanliness and
Filter
foreign objects
Suction Tube
Visually inspect filter screen for cleanliness.
Filter Screen
Decon Solution
1. Visually inspect exterior surface for
Tank
cracks and or leaks.
2. Visually inspect quick disconnect for
damage and or O-ring for leaks.
3. Visually check Decon solution level.
Injector
Visually inspect exterior for damage and or
Assembly
leaks.
BURNER
Burner Air
Visually inspect for excessive soot buildup.
Adjustment
PROCEDURE
0013-3
0013
EQUIPMENT NOT
READY/
AVAILABLE IF:
If filter is dirty, and
or clogged. Clean
or replace filter
If filter screen is
dirty and or
clogged. Clean or
replace filter
screen.
If solution tank
exterior is cracked
and or leaking
solution. Replace
tank.
If quick disconnect
is damaged or O-
ring is worn and or
cut. Replace quick
disconnect or O-
ring.
If level is low, refill.
If exterior is
damaged and or
leaking. Replace
assembly.
If excessive soot
buildup is detected.
Burner requires
service by
authorized service
technician. Contact
Reeves EMS.
DHS Systems LLC