Operation & Maintenance w/IPB
INITIAL SETUP:
References
WP 000X
TROUBLESHOOTING PROCEDURES
This work package contains general information for troubleshooting the G2 Series Decontamination Water Heater by
qualified personnel. A qualified person is one who is familiar with this manual, the operation of the G2
Decontamination Water Heater and the hazards involved in its operation and maintenance. The work package
provides a systematic approach to locating and correcting malfunction of the G2 Series Decontamination Water
Heater. Each section is arranged according to the condition/indication of a problem. The corrective action items have
been arranged in order of complexity, with the simpler actions listed first. Note that troubleshooting causes and
actions beyond the scope of operator level qualified personnel are not included in the WP. If a course of action does
not present itself, contact Reeves EMS.
The most important step of troubleshooting is to gather as much first-hand information as possible from the personnel
who were present when the problem or failure occurred. Information as to how long the G2 Series Decontamination
Water Heater has been operating, what systems were connected, whether any protective equipment or devices
functioned, etc., can also help isolate a problem. Note that if in any doubt about how to proceed, contact Reeves
EMS before taking action.
Tools, equipment, clothing and your body must be kept clear of all electrical connections,
while power is applied to the system
Voltage sources, in addition to being an electrical shock hazard, may also potentially produce
serious burns. Care should be exercised when using hand tools around exposed power
connectors. Never let tools bridge two terminals.
If the circuit breaker does not stay in the ON position when energized, DO NOT attempt to
energize repeatedly. This could cause damage to the surge protector or other components.
Instead, investigate and identify the cause of the problem. Correct the situation before
attempting to energize breaker again.
To avoid electrical shock and damage to the equipment, ensure the power cord is
disconnected at the power source before removing or replacing any items.
Part Number: 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
G2 Series Decontamination Water Heater
OPERATOR TROUBLESHOOTING PROCEDURES
G2 SERIES DECONTAMINATION WATER HEATER
MECHANICAL TROUBLESHOOTING PROCEDURES
WARNING
0010-1
0010
DHS Systems LLC