Reeves G2 series Operation Manual page 30

G2 series decontamination water heater
Hide thumbs Also See for G2 series:
Table of Contents

Advertisement

Operation & Maintenance w/IPB
VENTILATION INSTRUCTIONS (CONT)
If the unit is being installed in an enclosed room, an adequate air supply must be provided to the burner by installing
openings near the floor. These openings should be at least one square inch per 1000 BTU input of the machine.
Also, a ventilation opening must be installed near the ceiling. This opening should be at least the same size as the
supply opening near the floor. Refer to NFPA 31 and CAN/CSA B139-M91, where applicable.
If the burner is located in a tightly constructed building where there is inadequate outside air infiltration, outside
combustion air must be supplied by some other means. One method to accomplish this is through a permanent
opening(s) must not be less than one square inch per 5,000 BTU input. All appliances must be taken into
consideration. Refer to NFPA 31 and CAN/CSA B139-M91, where applicable.
POWER CORD CONNECTION
This unit must be connected to a properly grounded outlet. DO NOT USE
an adapter or remove the third grounding prong.
1. Make certain the power switch is in the OFF position.
2. Ensure the electrical supply is a minimum of 15 amp / 110V.
3. GROUNDING INSTRUCTIONS:
a) This unit must be grounded. If it should malfunction or breakdown, grounding provides a path of least
resistance for electric current to reduce the risk of electric shock. This unit is equipped with a cord having
an equipment-grounding conductor. The plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
4. DANGER:
b) Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check
with a qualified electrician or Reeves EMS, if you are in doubt as to whether the outlet is properly
grounded. Do not modify the plug, if it will not fit the outlet; have a proper outlet installed by a qualified
electrician. Do not use any type of adapter with this unit.
5. GROUND FAULT CIRCUIT INTERRUPTER PROTECTION (GFCI):
c) SINGLE PHASE – if this water heater is provided with a Ground Fault Circuit Interrupter (GFCI) built into
the plug or power supply cord, test the GFCI each time it is plugged into an outlet according to the
instructions on the GFCI. Do not use the water heater if the test fails. The GFCI provides additional
protection from the risk of electrical shock. Should replacement of the plug or power cord become
necessary, use only identical replacement parts that include GFCI protection?
d) If this water heater is not provided with a GFCI, this water heater should only be connected to a
receptacle that is protected by a GFCI to comply with the National Electric Code (NFPA 70) and to
provide additional protection from the risk of electric shock.
Part Number: 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
G2 Series Decontamination Water Heater
WARNING
Risk of Electrocution
0005-2
0005
DHS Systems LLC

Advertisement

Table of Contents
loading

This manual is also suitable for:

G2sG2s-i

Table of Contents