REMOVE AND REPLACE DECON SOLUTION TANK STRAINER (G2-I WATER HEATER ONLY)
INITIAL SETUP:
Tools and Special Tools
General Mechanics Tool Kit
Materials/Parts
Clean Water
REMOVAL OF DECON SOLUTION TANK STRAINER:
1. Disconnect power cord from power supply
2. Disconnect solution hose from the QCD at solution tank.
3. Unscrew solution in-line tube from solution tank.
4. Carefully remove in-line tube from tank; gently pull straight up to remove tube and strainer.
5. Remove strainer from tube.
6. Clean/rinse strainer in clean water.
7. Inspect strainer for damages; if necessary replace with a new strainer.
INSTALLATION OF DECON SOLUTION TANK STRAINER:
8. Install strainer onto in-line tube.
9. Install in-line tube into solution tank; turn solution in-line tube CW and tighten.
10. Reconnect solution hose to the QCD at the solution tank.
11. Reconnect power cord into the power supply.
END OF TASK
Part Number: 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
G2 Series Decontamination Water Heater
Personnel Required
One
Equipment Condition
Equipment Powered Down
Power Source Disconnected
0014-18
0014