REMOVE AND REPLACE ELECTRONIC IGNITER ASSEMBLY
INITIAL SETUP:
Tools and Special Tools
General Mechanics Tool Kit
Materials/Parts
REMOVAL OF THE ELECTRONIC IGNITER ASSEMBLY:
1. Remove the electronic igniter assembly as follows:
a. Disconnect power cord from power supply outlet.
b. Using a cross-point screwdriver, remove the bottom (2) screws from the electronic igniter and base
plate assembly.
c. Using a 5/16" open end wrench or equivalent, remove the top (2) hex head screws from the electronic
igniter and base plate assembly.
d. Lift the electronic igniter and base plate assembly off of the burner motor.
e. Loosen and remove (2) wire nuts that secure the blue and white igniter wire to main wire harness.
f.
Using a 5/16" open end wrench, remove (2) hex head mounting screws from the electronic igniter and
base plate.
g. Remove the electronic igniter from the base plate.
REPLACEMENT OF THE ELECTRONIC IGNITER:
a. Feed/insert the blue and white igniter wire through the base plate.
b. Install (2) hex head mounting screws through the electronic igniter to the base plate.
c. Using a 5/16" open end wrench, tighten both mounting screws.
INSTALLATION OF THE ELECTRONIC IGNITER ASSEMBLY:
d. Place the electronic igniter and base plate assembly onto the burner motor
e. Reconnect the igniter blue wire to the black #011 main harness wire and the black wire from the oil
burner wire harness. Twist the three wires together and install a wire nut.
f.
Reconnect the igniter white wire to (3) white wires (one from the main wire harness, one from the oil
burner motor and one from the fuel solenoid plug). Twist wires together and install a wire nut.
g. Crimp wire nuts.
Part Number: 1006375
This document contains information proprietary to DHS Systems LLC and is intended solely for use by its customers. No portion of this document may be reproduced
for release to a third party without written consent of DHS Systems LLC.
G2 Series Decontamination Water Heater
PROCEDURES REQUIRE VERIFICATION
Personnel Required
One
Equipment Condition
Equipment Powered Down
Power Source Disconnected
0014-11